Inrush
Current (ACE-723A/B): Not
exceed 15A@115V AC or 30A@230V AC
|
|
Ripple
and Noise:
Less
than 100mV
|
|
Line Regulation:
The
line regulation for each output are less than
±1%,while measuring at rated loading and ±10%
of input voltage changing
|
|
Load Regulation:
Less
than ±1%@±5V and -12V, ±4%@+12V and +24V
(ACE-723B)
|
|
Efficiency:
Higher
than 75%
|
|
Hold-up
Time (ACE-723A/B)
20ms
(typical)@115V AC
|
|
Protection:
Over
voltage protection. The trip point is around
5.9V ~ 7.0V output
|
|
Thermal
Protection:
Built
in 110±5o
C
thermal switch in HS1
|
|
Altitude:
0
~10,000ft
|
|
Vibration:
10
~ 55Hz at 2G 3min. period, 30 min. along X,
Y and Z axis
|
|
Impact:
10G
for 20ms once on each X, Y and Z axis
|
|
|
|
Hi-pot
isolation:
-
4300V DC, input to output for one minute
-
2200V DC, input to ground for one minute
|
|
MTBF: -
ACE723A: 206,500 Hours
-
ACE723B: 206,300 Hours
-
ACE723T: 206,700 Hours
-
ACE723C: 205,900 Hours
|
|
Safety:
Meets
UL 478, 1012, 1950; CSA 22.2 No. 234, VDE EN
60 950
|
|
EMI:
Meets
FCC docket 20780 curve "A",
EN50081-2 : CISPR22 "A"
|
|
EMS Standard (Design to
meet the following
limits):
-
EN 50082-2
-
IEC 801-1 8KV (Air Discharge) criteria B
-
IEC 801-3, 10V/M criteria A
-
IEC 801-4, 2KV criteria B
-
IEC 801-5, 2KV criteria B
|
|
Built-in
cooling fan
|
|
Operating
Temperature:
-20~70oC
(Derating curve will occur 50~70oC
)
|
|
Storage
Temperature:
-20~85oC
|
|
Dimensions:
112(W)x51(H)x203(D)mm;
(4.4"x2"x 8")
|
|
|