Ripple
& Noise:
Less
than 50mV@ +5V; 100mV@ Others
|
|
Line Regulation:
The
line regulation for each outputs are less than
±1% @ +5V; ±3%@ -5V & -12V
|
|
Load Regulation:
Less
than ±3%@+5V & + 12V, ±5 % @ -5V & -12V
|
|
Efficiency:
Higher
than 70%
|
|
Hold-up Time
(ACE-870A/
870AP):
16ms
(typical)@115V AC
|
|
Altitude:
0~10,000ft
|
|
Protection:
Over
voltage protection. The trip point is around 5.7V
~ 7.0V output
|
|
|
MTBF:
-
ACE-870A: 296,831 Hours
- ACE-870T: 277,126 Hours
-
ACE-870C: 276,238 Hours
-
ACE-865V: 246,485 Hours
|
|
Safety:
Meets
UL 1950, CSA 22.2 No. 234, VDE EN 60 950
|
|
EMI:
-
ACE-870A/870AP : Meets FCC docket
20780 curve
"B"
-
ACE-870AP : Harmonic EN 61000-3-2
|
|
Operating
Temperature:
-20~70oC
(Derating curve will occur 50~70oC)
|
|
Storage
Temperature:
-20~85o
C
|
|
Dimensions:
81(W)
x 50(H) x 127(D)mm; (3.2"x 2"x 5")
|
|