|
Inrush
Current
(ACE-723A/B):
Not
exceed 15A@115V AC
or 30A@230V AC
|
|
Ripple
and Noise:
Less
than 100mV
|
|
Line
Regulation:
The
line regulation
for each output
are less than ±1%,while
measuring at rated
loading and ±10%
of input voltage
changing
|
|
Load
Regulation:
Less
than ±1%@±5V and
-12V, ±4%@+12V
and +24V
(ACE-723B)
|
|
Efficiency:
Higher
than 75%
|
|
Hold-up
Time (ACE-723A/B)
20ms
(typical)@115V AC
|
|
Protection:
Over
voltage
protection. The
trip point is
around 5.9V ~ 7.0V
output
|
|
Thermal
Protection:
Built
in 110±5o
C
thermal
switch in HS1
|
|
Altitude:
0
~10,000ft
|
|
Vibration:
10
~ 55Hz at 2G 3min.
period, 30 min.
along X, Y and Z
axis
|
|
Impact:
10G
for 20ms once on
each X, Y and Z
axis
|
|
|
|
Hi-pot
isolation:
-
4300V DC, input to
output for one
minute
-
2200V DC, input to
ground for one
minute
|
|
MTBF:
-
ACE723A: 206,500
Hours
-
ACE723B: 206,300
Hours
-
ACE723T: 206,700
Hours
-
ACE723C: 205,900
Hours
|
|
Safety:
Meets
UL 478, 1012,
1950; CSA 22.2 No.
234, VDE EN 60 950
|
|
EMI:
Meets
FCC docket 20780
curve "A",
EN50081-2 :
CISPR22 "A"
|
|
EMS
Standard (Design
to
meet the following
limits):
-
EN 50082-2
-
IEC 801-1 8KV (Air
Discharge)
criteria B
-
IEC 801-3, 10V/M
criteria A
-
IEC 801-4, 2KV
criteria B
-
IEC 801-5, 2KV
criteria B
|
|
Built-in
cooling fan
|
|
Operating
Temperature:
-20~70o
C
(Derating curve
will occur 50~70o
C
)
|
|
Storage
Temperature:
-20~85o
C
|
|
Dimensions:
112(W)x51(H)x203(D)mm;
(4.4"x2"x
8")
|
|
|